Huashi Box-type Substation
Chinese-style box-type substation integrating the HV switchgear, transformer and LV distribution equipment in a compact outdoor enclosure.

Chinese-style box-type substation integrating the HV switchgear, transformer and LV distribution equipment in a compact outdoor enclosure for urban and industrial distribution.
A compact substation transformer in the Chinese-style layout integrates the three functions tightly. This compact substation transformer is specified for urban and industrial distribution where a smaller cabinet is preferred.
How this family is built
Chinese-style compact arrangement
The Huashi (Chinese-style) box integrates the HV switchgear, transformer and LV board in one compact outdoor housing. Compared with the European three-compartment layout it is more tightly packaged, which lowers cost and footprint for urban and industrial distribution where the full compartmentalised layout is not required.
Construction and protection
The housing is a factory-built steel enclosure with thermal insulation, ventilation louvres and moisture protection, delivered as one assembly. Protection is typically IP54 or above; anti-condensation heaters and forced ventilation are added where the site is humid or the load is high.
Selection points
Confirm the HV and LV ratings, transformer capacity, incoming scheme and the short-circuit withstand. Type-test evidence to GB/T 17467 and IEC 62271-202 should be provided for the specific configuration.
Common models
HSH-10/0.4-630, HSH-12/0.4-1250
Typical parameters
| Parameter | Typical value | Basis |
|---|---|---|
| Electrical | ||
| Rated HV voltage | 10 kV or 12 kV, 3-phase, 50 Hz | GB/T 17467 |
| Rated LV voltage | 0.4 kV | GB/T 156 |
| Transformer capacity | 100 – 1600 kVA, per SLD | Huashi series range |
| HV side | RMU or load-break switch + fuse, 12 kV | Per SLD |
| LV side | Main breaker + feeder ways, per distribution schedule | Per SLD |
| Compartment layout | Integrated HV / transformer / LV arrangement | GB/T 17467 |
| Mechanical & environment | ||
| Enclosure | Al-Zn coated steel or stainless, 1.5 – 2.5 mm | Fabricator shell range |
| Ingress protection | IP54 as standard | GB/T 4208 |
| Ambient temperature | −35 to +40 °C | ZGS datasheet, same enclosure family |
| Altitude | ≤ 1000 m without derating | GB/T 17467 |
| Compliance & scope | ||
| Standards | GB/T 17467, IEC 62271-202 | Nameplate basis |
| Typical use | Urban and industrial distribution, roadside and compound siting | Product scope |
Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.
Frequently asked questions
QWhat information is needed to specify this item?
Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.
QAre the parameters on this page the final project values?
No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.
QWhat is included in the quotation?
The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.
QCan the item be adapted to a project drawing?
Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.
Related systems and items
The five functional systems show what this family is assembled from; send the diagram for a project BOM.
Need this quoted?
Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.