LV / Distribution System
Low-voltage switchgear and outgoing feeder circuits: LV switchboard (GGD/GCS/MNS), ACB, MCCB, disconnectors, ATS, LV CT, meter and SPD.
Low-voltage switchgear and outgoing feeder circuits: LV switchboard (GGD/GCS/MNS), ACB (CW1), MCCB (CM1), disconnectors, ATS, LV CT, multifunction meter and SPD, plus the capacitor compensation cabinet for reactive-power correction.
The LV switchgear panel distributes power to the outgoing circuits. Each LV switchgear panel here is graded by load current and fault level for selectivity.
Role in the substation
What the LV section contains
The low-voltage section distributes power to the outgoing circuits. It is built around a low-voltage switchboard — fixed type (GGD) or withdrawable type (GCS/MNS) — with air circuit breakers on the incoming feeder, moulded-case breakers on outgoing feeders, disconnectors, an automatic transfer switch for dual-source supply, LV current transformers, multifunction meters, surge protective devices and a capacitor bank for reactive-power correction.
Power quality and metering
Power-factor correction reduces reactive current and avoids penalties; harmonic filtering is added where non-linear loads are present. Multifunction meters provide voltage, current, power, energy and communications for remote monitoring. Select SPD class by the exposure of the site and coordinate it with the upstream breaker.
High-availability schemes
For critical loads such as data centres, a dual utility input with automatic transfer is common: both feeds share normal load, and on loss of one feed the remaining feed carries the full load. Battery/UPS, stored-energy and generator feeds are integrated for backup, while bus temperature monitoring and harmonic and unbalance measurement guard against the overheating and power-quality faults that cause downtime.
Items in this system

LV Switchgear Assembly (Whole Cabinet, GGD/GCS/MNS)
Low-voltage switchboard supplied as a complete cabinet (fixed GGD or withdrawable GCS/MNS). A real procurement object for EPCs and end users; internal breakers / CTs / meters are fitted but quoted at cabinet level.
Read more →
CW1 Frame Circuit Breaker (ACB)
Air circuit breaker (ACB / frame breaker) for the LV main incomer and large outgoing feeders; highest brand-grade sensitivity.
Read more →
CM1 Moulded-case Circuit Breaker (MCCB)
Moulded-case circuit breaker for LV outgoing feeder circuits; high consumption volume.
Read more →
Disconnector / Knife-fuse Switch
LV disconnector and knife-fuse switch for isolation and fuse protection.
Read more →
Automatic Transfer Switch (ATS)
Auto transfer switch for dual-source supply switching; standard for important loads.
Read more →
LV Current Transformer (LMZ)
LV current transformer for metering and measurement; ratio by specification.
Read more →
Multifunction Meter / Energy Meter
Power-parameter measurement and energy metering instrument; standard on intelligent LV boards.
Read more →
Surge Protective Device (SPD)
Lightning / surge protection device, selected by protection level.
Read more →Frequently asked questions
QWhat information is needed to specify this item?
Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.
QAre the parameters on this page the final project values?
No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.
QWhat is included in the quotation?
The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.
QCan the item be adapted to a project drawing?
Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.
Need this quoted?
Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.