Cable Terminal / Lug (DT)

Cable Terminal / Lug (DT) — Package Substation
Connectors

Cable Terminal / Lug (DT)

Basic consumable connecting cable to equipment; high turnover.

Copper10 – 240 mm²Tubular compression lugTerminal / lug
Cable Terminal / Lug (DT) — Package Substation

Basic consumable connecting cable to equipment; high turnover.

This item is specified against the single-line diagram and the site conditions; the common models and the parameter table below are the working reference, not a catalogue selection.

Substation Connectors — what this item does

Busbars, terminations and separables

Connectors carry current between the equipment and the network: fabricated copper busbars, cable lugs, termination kits, elbow separators and support insulators. On American-style substations the 200 A / 600 A load-break elbow is the key interface and is ordered to the bushing standard.

Workmanship and contact resistance

Most field failures at connections come from poor preparation, wrong torque or corrosion. Use the correct lug and die, clean and tin-plate copper busbar joints, apply the specified torque and protect outdoor joints against moisture.

Common models

DT-120 cable lug (120 mm2), DT-240 cable lug (240 mm2), OT / DT tubular lugs

Typical parameters

ParameterTypical valueBasis
Electrical
MaterialCopper, annealed, tin-plated optionDT model code
Conductor range10 – 240 mm²DT model range
TypeTubular compression lug (DT), ring lug (OT)Product variant
Bolt sizeM8 / M10 / M12, per lug and busbarProduct range
PlatingBare annealed copper or tin-platedProduct variant
Mechanical & environment
CrimpingHexagonal compression die, per lug sizeTooling table
BarrelSeamless or seamed barrel with inspection holeProduct design
Compliance & scope
StandardsGB/T 14315, IEC 61238-1Nameplate basis
Typical useCable termination at breakers, busbars and earth barsProduct scope

Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.

Frequently asked questions

QWhat information is needed to specify this item?
A

Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.

QAre the parameters on this page the final project values?
A

No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.

QWhat is included in the quotation?
A

The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.

QCan the item be adapted to a project drawing?
A

Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.

Selection points for a cable terminal

A cable terminal or lug is selected by conductor material, cross-sectional area, bolt size, plating and the equipment interface. The connection must match the cable schedule and the terminal pad, not only the nominal cable size.

For quotation, provide conductor size, material, insulation type, lug hole or bolt requirement, installation environment and the applicable crimping or testing requirement. This prevents a physically compatible part from becoming an electrically or mechanically wrong substitute.

Need this quoted?

Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.

Request a quotation
Package Substation

Specialized in package substations, switchgear cabinets and distribution components for global B2B projects. Configuration and bill of materials are fixed against the single-line diagram; assembly, wiring and routine test follow that drawing.

6 / 10 / 35 kV · 100–3150 kVA · IP54+