Automatic Transfer Switch (ATS)
Auto transfer switch for dual-source supply switching; standard for important loads.

Auto transfer switch for dual-source supply switching; standard for important loads.
This item is specified against the single-line diagram and the site conditions; the common models and the parameter table below are the working reference, not a catalogue selection.
LV Switchgear Panel — what this item does
Role of the LV components
Low-voltage components handle incoming, distribution and protection on the 0.4 kV side: air and moulded-case circuit breakers, disconnectors, transfer switches, current transformers, meters and surge protective devices. Their ratings follow the load current and the fault level at the LV bus.
Selectivity and power quality
Breakers should be graded so a downstream fault trips only the nearest device. Add reactive-power compensation and harmonic treatment where the load demands it, and choose the SPD class to the site’s lightning exposure.
Common models
PC class (e.g. SQ30-100/4P), CB class (e.g. CDQ7-250/4P)
Typical parameters
| Parameter | Typical value | Basis |
|---|---|---|
| Electrical | ||
| Rated voltage | 400 V | ATS model code |
| Rated current | 100 – 250 A (SQ30-100 / CDQ7-250) | Model code |
| Poles | 3P / 4P | Product variant |
| Class | PC class (load-break) or CB class (with protection) | GB/T 14048.11 |
| Transfer mode | Automatic, with manual emergency operation | Product design |
| Controller | Voltage-sensing controller, adjustable delay | Product design |
| Mechanical & environment | ||
| Mounting | Floor-standing cabinet or panel | Product variant |
| Ambient temperature | −5 to +40 °C | GB/T 14048.11 |
| Compliance & scope | ||
| Standards | GB/T 14048.11, IEC 60947-6-1 | Nameplate basis |
| Typical use | Dual-source transfer between grid and generator | Product scope |
Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.
Frequently asked questions
QWhat information is needed to specify this item?
Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.
QAre the parameters on this page the final project values?
No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.
QWhat is included in the quotation?
The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.
QCan the item be adapted to a project drawing?
Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.
Need this quoted?
Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.