Cable Termination Kit
Cable end termination and insulation, selected by voltage class (cold-shrink / heat-shrink).

Cable end termination and insulation, selected by voltage class (cold-shrink / heat-shrink).
This item is specified against the single-line diagram and the site conditions; the common models and the parameter table below are the working reference, not a catalogue selection.
Modular Substation Cable Termination Design — what this item does
Busbars, terminations and separables
Connectors carry current between the equipment and the network: fabricated copper busbars, cable lugs, termination kits, elbow separators and support insulators. On American-style substations the 200 A / 600 A load-break elbow is the key interface and is ordered to the bushing standard.
Workmanship and contact resistance
Most field failures at connections come from poor preparation, wrong torque or corrosion. Use the correct lug and die, clean and tin-plate copper busbar joints, apply the specified torque and protect outdoor joints against moisture.
Common models
10 kV cold-shrink termination kit, 10 kV heat-shrink termination kit, 8.7/15 kV three-core termination
Typical parameters
| Parameter | Typical value | Basis |
|---|---|---|
| Electrical | ||
| Rated voltage | 8.7/15 kV (10 kV class) | Kit model code |
| Type | Cold-shrink or heat-shrink, three-core | Product variant |
| Application | Indoor or outdoor termination | Product variant |
| Conductor range | 70 – 240 mm² | Kit range |
| Conductor material | Copper or aluminium, with the matching lug | Kit variant |
| Mechanical & environment | ||
| Stress control | Pre-formed stress cone or stress-control tape | Kit design |
| Sealing | Heat-shrink or cold-shrink sheds, mastic at the sheath | Kit design |
| Shed profile | Per creepage class for the site pollution level | GB/T 12706.4 |
| Compliance & scope | ||
| Standards | GB/T 12706.4, IEC 60502-4 | Nameplate basis |
| Typical use | HV cable termination at switchgear and transformer bushings | Product scope |
Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.
Frequently asked questions
QWhat information is needed to specify this item?
Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.
QAre the parameters on this page the final project values?
No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.
QWhat is included in the quotation?
The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.
QCan the item be adapted to a project drawing?
Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.
Need this quoted?
Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.