Transformer System

Dry-type transformer — Package Substation
Primary Systems

Transformer System

The core power-transforming unit: dry-type (SCB), oil-immersed (S11/S13) or amorphous-alloy (SH15) transformer, complete with controller and cooling or relay and gauge.

Primary systemBOM-linkedEngineer-specified
Dry-type transformer — Package Substation

The core power-transforming unit of the package substation: a dry-type (SCB), oil-immersed (S11/S13) or amorphous-alloy (SH15) transformer, supplied complete with temperature controller and cooling fans (dry-type) or Buchholz relay and oil-level gauge (oil-immersed). Typical capacity 315-1250 kVA.

The package substation transformer is the heart of the assembly. This package substation transformer section compares dry, oil and amorphous cores and the losses of each.

Role in the substation

Dry, oil-immersed or amorphous core

The transformer is the core of the package. Three constructions are common: epoxy-cast dry-type (SCB), oil-immersed (S11/S13) and amorphous-alloy (SH15). Dry-type units are chosen where fire safety matters — no oil, low smoke, insensitive to humidity — and are typically supplied with a temperature controller and cooling fans. Oil-immersed units are economical at higher ratings and use a sealed tank with a gas relay and oil level indication.

Losses and how they are reduced

Transformer losses split into no-load (iron) loss — hysteresis and eddy-current loss in the core — and load (copper) loss, the I²R heating in the windings. Published low-loss designs use grain-oriented cold-rolled silicon steel and continuous wound cores with vacuum annealing; for the 35 kV class, no-load losses are reported about 30% and load losses about 25% below the GB/T 6451 baseline. Amorphous cores reduce no-load loss further, which pays back where the transformer is lightly loaded for long periods.

Oil condition and maintenance

Where oil is used, it provides insulation, cooling and arc suppression, and protects internal metal parts from moisture and oxygen. Its condition is tracked by acid value, dielectric strength, water content and dissolved-gas analysis. Under GB/T 7595-2017, guidance values such as acid value above 0.1 mgKOH/g, dielectric strength below 30 kV/2.5 mm or water above 30 ppm trigger investigation or treatment; a sealed corrugated tank keeps oil away from air and slows ageing.

Amorphous-alloy dry transformers

Amorphous-alloy dry transformers are reported to reach efficiencies above 97% at rated load — roughly two to three percentage points higher than conventional units — because the amorphous strip has much lower hysteresis loss. With no oil they are also low-noise, fire-safe and moisture-tolerant, which suits factories, commercial buildings, schools, hospitals and renewable generation.

Items in this system

Main Transformer (Dry-type / Oil-immersed / Amorphous) — Package Substation

Main Transformer (Dry-type / Oil-immersed / Amorphous)

Single BOM line for the transformer. The content page splits by type: dry-type (SCB10/11/12/13), oil-immersed (S11/S13) and amorphous-alloy (SH15). Cooling fan, temperature controller and gas relay ship complete with the unit.

Read more →

Frequently asked questions

QWhat information is needed to specify this item?
A

Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.

QAre the parameters on this page the final project values?
A

No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.

QWhat is included in the quotation?
A

The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.

QCan the item be adapted to a project drawing?
A

Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.

Transformer product families

Package substations can be configured with different transformer families depending on voltage level, capacity, cooling method, indoor or outdoor installation, fire requirements, mining conditions and the project standard. The model names below are product-family references for configuration, not a substitute for confirming the final rating against the single-line diagram and site conditions.

Dry-type transformers

SC(B) epoxy-resin cast dry-type transformer for indoor or protected installations.

SC(Z)B dry-type transformer family where tap-changing requirements need to be reviewed.

SG10 three-phase dry-type transformer family for distribution applications.

SHC(B) amorphous-alloy dry-type transformer family for projects focused on lower no-load losses.

Dry-type enclosure options for installations requiring additional protection around the transformer.

Oil-immersed transformers

S11-M oil-immersed distribution transformer family for conventional distribution duties.

S13-M oil-immersed distribution transformer family for projects reviewing no-load loss performance.

SH15 amorphous-alloy oil-immersed transformer family for lower no-load loss applications.

SFZ11-35 kV oil-immersed power transformer family where higher-voltage and tap-changing requirements apply.

SFSZ11-110 kV three-phase power transformer family for higher-voltage project configurations.

Special application transformers

KBSG2-T flameproof dry-type mining transformer family for projects with specific underground or hazardous-area requirements.

KS11 oil-immersed mining transformer family for mining power distribution configurations.

Special application selection must confirm the site classification, enclosure requirement, cooling, protection, transport limits and applicable local standard before quotation.

What to confirm for the final model

Send the primary and secondary voltage, transformer kVA, frequency, tap range, cooling method, installation altitude, ambient temperature, enclosure or fire requirement, short-circuit level, noise limit and the project standard. The final datasheet, loss values, dimensions and accessories are confirmed from those inputs.

Request a transformer configuration review with the single-line diagram and site conditions.

Need this quoted?

Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.

Request a quotation
Package Substation

Specialized in package substations, switchgear cabinets and distribution components for global B2B projects. Configuration and bill of materials are fixed against the single-line diagram; assembly, wiring and routine test follow that drawing.

6 / 10 / 35 kV · 100–3150 kVA · IP54+