JDZ Voltage Transformer (PT)

JDZ Voltage Transformer (PT) — Package Substation
HV Components

JDZ Voltage Transformer (PT)

Voltage transformer for metering and voltage signal acquisition on the HV side.

10/0.1 kV30 – 50 VA0.5 / 1 / 3Voltage transformer
JDZ Voltage Transformer (PT) — Package Substation

Voltage transformer for metering and voltage signal acquisition on the HV side.

This item is specified against the single-line diagram and the site conditions; the common models and the parameter table below are the working reference, not a catalogue selection.

Substation Transformer Voltage — what this item does

Role of the HV components

High-voltage components perform switching, protection, measurement and indication. The load switch carries normal current, the current-limiting fuse clears transformer faults, the surge arrester clamps overvoltage, and CT/PT supply metering and protection signals. Each is selected against the system voltage and short-circuit level.

Coordination matters as much as the part

A component only protects the installation if its rating is coordinated with the rest of the feeder — fuse curves with cable and transformer withstand, arrester rating with system earthing, and CT accuracy class with the relay. Always check the type-test report and the applicable IEC 62271 / IEC 60099 / IEC 61869 part for the exact model.

Common models

JDZ10-10 (10/0.1 kV), JDZX10-10 (earthed-type 10/0.1 kV), JDZ10-10R (fuse-protected)

Typical parameters

ParameterTypical valueBasis
Electrical
Rated voltage ratio10/0.1 kVJDZ10-10 model code
Burden30 – 50 VA, per accuracy classGB/T 20840.3
Accuracy class0.5 / 1 / 3Product variant
Rated frequency50 HzGB/T 20840.3
Mechanical & environment
TypeSingle-phase, epoxy-cast, indoorProduct design
EarthingEarthed-type variant (JDZX) for phase-to-earth measurementProduct variant
FuseHV fuse protection option (JDZ10-10R)Product variant
Compliance & scope
StandardsGB/T 20840.3, IEC 61869-3Nameplate basis
Typical useMetering and voltage sensing in MV switchgearProduct scope

Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.

Frequently asked questions

QWhat information is needed to specify this item?
A

Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.

QAre the parameters on this page the final project values?
A

No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.

QWhat is included in the quotation?
A

The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.

QCan the item be adapted to a project drawing?
A

Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.

Need this quoted?

Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.

Request a quotation
Package Substation

Specialized in package substations, switchgear cabinets and distribution components for global B2B projects. Configuration and bill of materials are fixed against the single-line diagram; assembly, wiring and routine test follow that drawing.

6 / 10 / 35 kV · 100–3150 kVA · IP54+

© 2026 Package Substation. All rights reserved.PrivacyContactmanager@packagesubstation.com