KBSGZY Mining Flameproof Substation
Flameproof mining mobile substation for coal mines and other hazardous mining environments, with explosion-proof enclosure and KBSGZY series transformer.

Flameproof mining mobile substation for coal mines and other hazardous mining environments, with explosion-proof enclosure and KBSGZY series transformer.
A mobile substation transformer for mining duty is built for moving faces and hazardous air. This mobile substation transformer uses a dry, flameproof enclosure rather than oil.
How this family is built
Flameproof construction for hazardous areas
The KBSGZY type is the mobile, flameproof substation used in coal mines and other hazardous working environments. The transformer and switchgear are enclosed in an explosion-proof housing so that an internal fault cannot ignite the surrounding atmosphere; the unit is skid-mounted and can be moved as mining faces advance.
Dry transformer and protection
These units use a dry-type transformer rather than oil, which removes the fire and spill hazard underground. Protection follows mining rules — leakage, overcurrent, short-circuit and temperature trips — and the enclosure is built to the applicable explosion-protection standard (GB 3836 series).
Selection points
State the gas hazard group, the incoming voltage (6 or 10 kV), the required kVA rating and the moving method. Because the operating environment is severe, request the explosion-protection certificate and the type-test report for the exact model.
Common models
KBSGZY-500/6, KBSGZY-800/6, KBSGZY-1000/10
Typical parameters
| Parameter | Typical value | Basis |
|---|---|---|
| Electrical | ||
| Rated HV voltage | 6 kV or 10 kV, 3-phase, 50 Hz | GB 3836; MT/T mining standards |
| Rated LV voltage | 0.69 kV / 1.2 kV / 3.3 kV typical | Mine distribution voltages |
| Capacity | 200 – 1000 kVA typical, per face load | KBSGZY series range |
| Enclosure type | Flameproof, Ex d I for coal-mine service | GB 3836.1 / GB 3836.2 |
| HV side | Flameproof cable coupler, interlocked with the switch | GB 3836.1 |
| LV side | Flameproof outlet with earth-fault and leakage protection | MT/T mining standards |
| Mechanical & environment | ||
| Mobility | Skid-mounted, rail or track transport, relocatable between faces | KBSGZY design |
| Cooling | ONAN (oil) or AN (dry), sealed tank | GB/T 1094 |
| Ambient temperature | −20 to +40 °C, relative humidity ≤ 95 % | Mine environment |
| Ingress protection | IP54 on the flameproof enclosure | GB/T 4208 |
| Compliance & scope | ||
| Standards | GB 3836.1, GB 3836.2, GB/T 1094, MT/T mining standards | Nameplate basis |
| Service | Coal mine and hazardous mining environment, relocatable between faces | Product scope |
| Marking | MA mining-product safety mark required for coal-mine use | China MA scheme |
Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.
Frequently asked questions
QWhat information is needed to specify this item?
Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.
QAre the parameters on this page the final project values?
No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.
QWhat is included in the quotation?
The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.
QCan the item be adapted to a project drawing?
Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.
Related systems and items
The five functional systems show what this family is assembled from; send the diagram for a project BOM.
Need this quoted?
Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.