LV Power / Control Cable (YJV-0.6/1 kV)
Low-voltage power and control cable for outgoing and control circuits; large project volume.

Low-voltage power and control cable for outgoing and control circuits; large project volume.
This item is specified against the single-line diagram and the site conditions; the common models and the parameter table below are the working reference, not a catalogue selection.
LV Cable IEC Standard — what this item does
Choosing cable size and insulation
Cables are selected by voltage class, conductor cross-section, current-carrying capacity and installation method. XLPE-insulated power cable is used for HV distribution and for LV power and control circuits; screen and armour are specified by the earthing and mechanical requirements of the route.
Termination and routing
Allow for bending radius, derating in bundled or buried runs and the interface with the termination kit. Correct cable sizing keeps voltage drop and heating within limits over the life of the installation.
Common models
YJV-0.6/1 kV 4×95+1×50, KVV-450/750 V 4×2.5, KVVP shielded control cable
Typical parameters
| Parameter | Typical value | Basis |
|---|---|---|
| Electrical | ||
| Rated voltage | 0.6/1 kV (power), 450/750 V (control) | YJV / KVV model code |
| Conductor | Copper, 4 × 95 + 1 × 50 mm² power; 4 × 2.5 mm² control | Model range |
| Insulation | XLPE (YJV) or PVC (KVV, KVVP) | GB/T 12706.1 |
| Screen | Copper braid or tape on shielded control cable (KVVP) | Product variant |
| Core count | Per wiring schedule (multi-core, with or without neutral) | Per project |
| Mechanical & environment | ||
| Max conductor temperature | 70 °C PVC, 90 °C XLPE | GB/T 12706.1 |
| Bending radius | 10 × D (power), 6 × D (control) | Installation practice |
| Installation | Tray or duct inside the cabin, glanded entry | Per project |
| Compliance & scope | ||
| Standards | GB/T 12706.1, GB/T 9330, IEC 60502-1 | Nameplate basis |
| Typical use | LV power and control wiring inside the substation | Product scope |
Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.
Frequently asked questions
QWhat information is needed to specify this item?
Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.
QAre the parameters on this page the final project values?
No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.
QWhat is included in the quotation?
The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.
QCan the item be adapted to a project drawing?
Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.
Need this quoted?
Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.