DXN Live Indication Device

DXN Live Indication Device — Package Substation
HV Components

DXN Live Indication Device

HV-cabinet safety accessory for live-line indication; high replacement demand.

12 kVThree-phase LED indicationAC/DC 220 VLive indicator
DXN Live Indication Device — Package Substation

HV-cabinet safety accessory for live-line indication; high replacement demand.

A live indicator provides the visible safety signal on an HV cabinet and interlocks with earthing where specified.

This item is specified against the single-line diagram and the site conditions; the common models and the parameter table below are the working reference, not a catalogue selection.

Kiosk Substation Components — what this item does

Role of the HV components

High-voltage components perform switching, protection, measurement and indication. The load switch carries normal current, the current-limiting fuse clears transformer faults, the surge arrester clamps overvoltage, and CT/PT supply metering and protection signals. Each is selected against the system voltage and short-circuit level.

Coordination matters as much as the part

A component only protects the installation if its rating is coordinated with the rest of the feeder — fuse curves with cable and transformer withstand, arrester rating with system earthing, and CT accuracy class with the relay. Always check the type-test report and the applicable IEC 62271 / IEC 60099 / IEC 61869 part for the exact model.

Common models

DXN-G (indication type), DXN-Q (forced-locking type)

Typical parameters

ParameterTypical valueBasis
Electrical
Rated voltage12 kVDXN-12 model code
Sensor principleCapacitive divider on the bushing or busbarProduct design
IndicationThree-phase LED indication, self-checkProduct design
Interlock outputForced-locking contact for the earthing switch (DXN-Q)Product variant
Auxiliary supplyAC/DC 220 V, per variantProduct variant
Mechanical & environment
MountingPanel-front, wired to the capacitive sensorsProduct design
Ambient temperature−25 to +40 °CGB/T 11022
Compliance & scope
StandardsGB/T 11022, product technical specificationNameplate basis
Typical useHV live-line indication and earthing-switch interlockProduct scope

Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.

Frequently asked questions

QWhat information is needed to specify this item?
A

Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.

QAre the parameters on this page the final project values?
A

No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.

QWhat is included in the quotation?
A

The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.

QCan the item be adapted to a project drawing?
A

Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.

Need this quoted?

Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.

Request a quotation
Package Substation

Specialized in package substations, switchgear cabinets and distribution components for global B2B projects. Configuration and bill of materials are fixed against the single-line diagram; assembly, wiring and routine test follow that drawing.

6 / 10 / 35 kV · 100–3150 kVA · IP54+

© 2026 Package Substation. All rights reserved.PrivacyContactmanager@packagesubstation.com