HXGN-12 Ring Main Unit (Whole Cabinet)

HXGN-12 Ring Main Unit (Whole Cabinet) — Package Substation
Whole Procured Assemblies

HXGN-12 Ring Main Unit (Whole Cabinet)

Box-type SF6-insulated ring main unit supplied as a complete cabinet. Load switch, fuse, arrester, CT/PT and live indicator are integrated by the manufacturer; selected by connection scheme (incomer + transformer feeder loops).

12 kV630 A20 kARing main unit
HXGN-12 Ring Main Unit (Whole Cabinet) — Package Substation

Box-type SF6-insulated ring main unit supplied as a complete cabinet. Load switch, fuse, arrester, CT/PT and live indicator are integrated by the manufacturer; selected by connection scheme (incomer + transformer feeder loops).

This item is specified against the single-line diagram and the site conditions; the common models and the parameter table below are the working reference, not a catalogue selection.

RMU Ring Main Unit Types — what this item does

Where a ring main unit fits

A ring main unit is the compact MV solution for ring and radial distribution: load switch, fuse, arrester and indicators are integrated in a sealed cabinet. It is selected by connection scheme and fault level; use a withdrawable breaker cabinet instead where there are many feeders or breaker-only protection is required.

Common models

HXGN15-12/630 (SF6 RMU), HXGN15-12/1250-31.5, HXGN-12F (air-insulated), XGN15-12

Typical parameters

ParameterTypical valueBasis
Electrical
Rated voltage12 kVHXGN-12 datasheet
Rated current630 A (1250 A variant)HXGN-12 datasheet
Rated breaking current20 kAHXGN-12 datasheet
Short-time withstand20 kA / 4 sGB/T 3906
Power-frequency withstand42 kV / 1 minGB/T 11022
Lightning impulse withstand75 kVGB/T 11022
Busbar rating630 A, copperPer SLD
Mechanical & environment
Insulation mediumSF6 (HXGN15) or air (HXGN-12F)Product variant
Operating mechanismManual spring, motorised optionProduct variant
Ingress protectionIP3X indoor, IP54 with outdoor enclosureGB/T 4208
Ambient temperature−25 to +40 °CGB/T 3906
Altitude≤ 1000 m without deratingGB/T 11022
Compliance & scope
StandardsGB/T 3906, GB/T 11022, IEC 62271-200Nameplate basis
Typical useRing network, urban and industrial distributionProduct scope

Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.

Frequently asked questions

QWhat information is needed to specify this item?
A

Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.

QAre the parameters on this page the final project values?
A

No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.

QWhat is included in the quotation?
A

The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.

QCan the item be adapted to a project drawing?
A

Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.

Need this quoted?

Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.

Request a quotation
Package Substation

Specialized in package substations, switchgear cabinets and distribution components for global B2B projects. Configuration and bill of materials are fixed against the single-line diagram; assembly, wiring and routine test follow that drawing.

6 / 10 / 35 kV · 100–3150 kVA · IP54+

© 2026 Package Substation. All rights reserved.PrivacyContactmanager@packagesubstation.com