Prefabricated Substation Enclosure (Cabin)

Prefabricated Substation Enclosure (Cabin) — Package Substation
Whole Procured Assemblies

Prefabricated Substation Enclosure (Cabin)

Factory-built steel / non-metallic enclosure integrating HV, transformer and LV compartments. Supplied complete (frame, doors, locks, seals, base skid) – never purchased as loose parts.

10 / 12 kV0.4 kV100 – 1600 kVAPrefab enclosure
Prefabricated Substation Enclosure (Cabin) — Package Substation

Factory-built steel / non-metallic enclosure integrating HV, transformer and LV compartments. Supplied complete (frame, doors, locks, seals, base skid) – never purchased as loose parts.

A prefab enclosure is bought as one complete, factory-tested assembly — frame, doors, seals and base skid included, never as loose parts.

This item is specified against the single-line diagram and the site conditions; the common models and the parameter table below are the working reference, not a catalogue selection.

Prefabricated Substation Enclosure — what this item does

Why these are bought as complete assemblies

Whole assemblies — the cabin, transformer, ring main unit, withdrawable switchgear, LV board and compensation cabinet — are procured as complete, factory-tested objects rather than as loose parts. The manufacturer integrates the internal devices and issues the type-test and routine-test documentation, which keeps responsibility with one supplier and shortens site assembly.

What to check on a complete assembly

Confirm the rated voltage and current, the short-circuit withstand, the protection degree, the applicable standard and the interface drawing. For the transformer, state the winding type, loss level and vector group; for switchgear, state the breaking capacity and the operating mechanism.

Common models

European-style enclosure (YBM(P)12), American-style enclosure (ZGS), Compact European-style (YB), Non-metallic GRC enclosure, Custom per drawing

Typical parameters

ParameterTypical valueBasis
Electrical
Rated HV voltage10 / 12 kVGB/T 17467
Rated LV voltage0.4 kVGB/T 156
Transformer accommodated100 – 1600 kVA, per SLDYB / ZGS range
HV compartmentRMU or KYN28-type, 12 kV, 630 APer SLD
LV compartmentMain busbar to 1600 APer transformer rating
Mechanical & environment
Shell materialAl-Zn coated steel 1.5 – 2.5 mm, stainless or GRC optionTianjin Zhongtuo shell range
CompartmentsHV / transformer / LV, separate and metal-partitionedGB/T 17467
Ingress protectionIP54+ as standardGB/T 4208
Ambient temperature−35 to +40 °CZGS datasheet
Altitude≤ 1000 m without deratingZGS datasheet
Doors and sealsDouble-leaf doors, padlockable locks, EPDM gasketsFabricator standard
BaseSkid or concrete plinth, per sitePer project
Compliance & scope
StandardsGB/T 17467, IEC 62271-202Nameplate basis
OptionsDoors, locks, hinges, seals, base skid, lighting, cable glandsPer BOM
ScopeShell, doors, partitions, base frame, lighting, earthing terminalsPer BOM

Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.

Frequently asked questions

QWhat information is needed to specify this item?
A

Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.

QAre the parameters on this page the final project values?
A

No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.

QWhat is included in the quotation?
A

The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.

QCan the item be adapted to a project drawing?
A

Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.

Need this quoted?

Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.

Request a quotation
Package Substation

Specialized in package substations, switchgear cabinets and distribution components for global B2B projects. Configuration and bill of materials are fixed against the single-line diagram; assembly, wiring and routine test follow that drawing.

6 / 10 / 35 kV · 100–3150 kVA · IP54+

© 2026 Package Substation. All rights reserved.PrivacyContactmanager@packagesubstation.com