Prefabricated Substation Enclosure (Cabin)
Factory-built steel / non-metallic enclosure integrating HV, transformer and LV compartments. Supplied complete (frame, doors, locks, seals, base skid) – never purchased as loose parts.

Factory-built steel / non-metallic enclosure integrating HV, transformer and LV compartments. Supplied complete (frame, doors, locks, seals, base skid) – never purchased as loose parts.
A prefab enclosure is bought as one complete, factory-tested assembly — frame, doors, seals and base skid included, never as loose parts.
This item is specified against the single-line diagram and the site conditions; the common models and the parameter table below are the working reference, not a catalogue selection.
Prefabricated Substation Enclosure — what this item does
Why these are bought as complete assemblies
Whole assemblies — the cabin, transformer, ring main unit, withdrawable switchgear, LV board and compensation cabinet — are procured as complete, factory-tested objects rather than as loose parts. The manufacturer integrates the internal devices and issues the type-test and routine-test documentation, which keeps responsibility with one supplier and shortens site assembly.
What to check on a complete assembly
Confirm the rated voltage and current, the short-circuit withstand, the protection degree, the applicable standard and the interface drawing. For the transformer, state the winding type, loss level and vector group; for switchgear, state the breaking capacity and the operating mechanism.
Common models
European-style enclosure (YBM(P)12), American-style enclosure (ZGS), Compact European-style (YB), Non-metallic GRC enclosure, Custom per drawing
Typical parameters
| Parameter | Typical value | Basis |
|---|---|---|
| Electrical | ||
| Rated HV voltage | 10 / 12 kV | GB/T 17467 |
| Rated LV voltage | 0.4 kV | GB/T 156 |
| Transformer accommodated | 100 – 1600 kVA, per SLD | YB / ZGS range |
| HV compartment | RMU or KYN28-type, 12 kV, 630 A | Per SLD |
| LV compartment | Main busbar to 1600 A | Per transformer rating |
| Mechanical & environment | ||
| Shell material | Al-Zn coated steel 1.5 – 2.5 mm, stainless or GRC option | Tianjin Zhongtuo shell range |
| Compartments | HV / transformer / LV, separate and metal-partitioned | GB/T 17467 |
| Ingress protection | IP54+ as standard | GB/T 4208 |
| Ambient temperature | −35 to +40 °C | ZGS datasheet |
| Altitude | ≤ 1000 m without derating | ZGS datasheet |
| Doors and seals | Double-leaf doors, padlockable locks, EPDM gaskets | Fabricator standard |
| Base | Skid or concrete plinth, per site | Per project |
| Compliance & scope | ||
| Standards | GB/T 17467, IEC 62271-202 | Nameplate basis |
| Options | Doors, locks, hinges, seals, base skid, lighting, cable glands | Per BOM |
| Scope | Shell, doors, partitions, base frame, lighting, earthing terminals | Per BOM |
Values are the working reference for this family and its standard models. On a project the rating, protection and cable schedule are confirmed against the single-line diagram and the site conditions before the quotation is issued.
Frequently asked questions
QWhat information is needed to specify this item?
Send the single-line diagram, rated voltage and current or capacity, short-circuit duty, installation environment, cable or terminal schedule, and any interface dimensions that apply to the item.
QAre the parameters on this page the final project values?
No. They are working reference values for the product family. The final model, rating, protection, accessories and scope are confirmed against the single-line diagram and site conditions before quotation.
QWhat is included in the quotation?
The quotation identifies the selected configuration, bill of materials, scope of supply and applicable test or document package. Loose accessories and site work are listed separately when applicable.
QCan the item be adapted to a project drawing?
Project-specific dimensions, interfaces and accessories can be reviewed against the drawings. Feasibility and the final configuration are confirmed for the selected model before production.
Need this quoted?
Send the single-line diagram and the site conditions. You get back a configuration, a bill of materials and a scope of supply — in writing, at quotation.